Verified test report
Analytical test report

Selank 10mg · RTT Peptides

Lot B6696 is one of 8 lots of Selank we have release-tested for this catalogue, scored on purity, quantity, and batch traceability. Independent third-party HPLC/MS verification of this lot is available on request.

9.0/10
A Great
Purity
3.0 / 4
Quantity
4.0 / 4
Identifier
2.0 / 2
The test score is calculated from purity (how much of the vial content is the expected compound, with values closest to 100% best and below 98% considered unacceptable), quantity (how close the measured amount is to the label claim, more than plus or minus 20% is unacceptable), and identifier (whether the batch this vial came from can be traced to a certificate).

Sample details

ProductSelank 10mg
Sample typeSealed retail vial
Date received30 Apr 2026
Physical detailsPrinted label / aluminium crimp / green cap

Test details

MethodRP-HPLC-UV + LC-MS
Tested on02 May 2026
Tested byRTT Peptides QC
ReportQC-22652

Score breakdown

Purity
98.97%
3.0 / 4

Measured purity by RP-HPLC-UV against the ≥ 98.0% release specification. Net peptide content 94.9%.

Quantity
10.1mg
4.0 / 4

Label claim 10mg, measured 10.1mg, divergence +1.0%. Within plus or minus 5% of label scores full marks.

Identifier
B6696
2.0 / 2

Batch identifier printed on the vial and traceable to this certificate, so the lot can be verified end to end.

Sample logistics

24 Apr 2026
Sample logged for release testing
30 Apr 2026
Received and processed at the QC facility
02 May 2026
Assayed by RP-HPLC-UV with LC-MS confirmation
03 May 2026
Certificate of analysis issued and released

Certificate authentication

Test certificate ID09ypmh0
ProductSelank 10mg from RTT Peptides
Batch IDB6696
Tested byRTT Peptides QC on 02 May 2026
Verification URL
https://www.rttpeptides.ca/verify/coa/selank-B6696/

Detailed certificate of analysis

RTT PEPTIDES · QUALITY ASSURANCE
Analytical release certificate · RP-HPLC-UV with LC-MS confirmation
Independent third-party verification available on request.
ReportQC-22652Issued2026-05-03Page1 of 1

Certificate of Analysis

Selank · Lot B6696
SampleSelank
Issued forRTT Peptides
Lot / BatchB6696
Label claim10mg
CAS129954-34-3
AppearanceWhite lyophilised powder
Date received2026-04-30
Date analysed2026-05-02

01 Purity by RP-HPLC-UV

050100150200 DAD 214 nm 8.61 min · 98.97% 0246810121416 Retention time (min) Absorbance (mAU)
Figure 1 · Reverse-phase HPLC-UV chromatogram at 214 nm. C18, 2.7 µm; gradient 0.1% TFA in water / acetonitrile at 1.0 mL/min.
Purity by RP-HPLC-UV: component retention time, peak area, and area percent
#ComponentRT (min)Area (mAU·s)Area %
1RRT 0.968.2526.50.63
2Selank ▸ main8.614156.798.97
3RRT 1.3811.9216.80.40
Purity (HPLC) 98.97% · net peptide content 94.9% · meets the ≥ 98.0% release specification.

02 Identity by LC-MS

Expected average mass751.89 Da
Observed mass752.10 Da
Identity confirmed · observed mass conforms to the expected structure of Selank.

03 Summary of results

Summary of results: test, method, specification, result, and outcome
TestMethodSpecificationResultOutcome
PurityRP-HPLC-UV, 214 nm≥ 98.0 %98.97 % Pass
IdentityLC-MS (ESI+)Consistent with structureConfirmed Pass
Net peptide contentBy differenceReport94.9 %n/a
AppearanceVisualWhite lyophilised powderConforms Pass
ReconstitutionBacteriostatic waterClear, particulate-freeConforms Pass

The submitted lot conforms to identity and meets the stated purity specification. Analysis was performed by RP-HPLC-UV with LC-MS confirmation. Results relate only to the lot as received and tested and do not constitute a certificate of any third party.

RELEASED QC · QC-22652 · 2026-05-03
Quality Assurance · RTT Peptides
RTT PEPTIDES · QUALITY RELEASED · 2026-05-03 RP Q·A
Issued under the RTT Peptides quality programme; this is the vendor's own release certificate. Independent third-party HPLC/MS verification of any lot is available on request. Products are supplied strictly as research reagents for in-vitro laboratory use only, not for human or animal consumption. Report QC-22652 · RP.

This is the vendor's own release certificate. Independent third-party HPLC/MS verification of this lot is available on request.